Precision Industrial RTDs
Model 5627A

5627s

Features

  • Vibration and shock resistant
  • 3/4-inch bend radius for increased durability
  • NVLAP-accredited calibration included

Specifications 

Resistance 

Nominal 100W 

Temperature Coefficient 

0.00385W/W/ °C nominal 

Temperature Range 

–200 °C to 420 °C
(5627-6 and 5627-9 to 300 °C; transition and cable temperature: 0 °C to 150 °C) 

Drift Rate 

±0.13 °C at 0 °C after 1000 hours at 400 °C 

Sheath Material 

316 Stainless Steel 

Leads 

Teflon™-insulated, nickel-plated stranded copper, 22 AWG 

Termination 

Specify. See Ordering Information. 

Time Constant 

Four seconds maximum for 63.2 %Response to step change in water moving at 3 fps. 

Bending Radius 

Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Hart lab requires 20 cm [8 in] of unbent sheath to re-calibrate.) 

Calibration 

Includes a NVLAP-accredited calibration and table with R vs. T values in 1 °C increments from –196 °C to 500 °C (to 300 °C for 5627-6 and 5627-9). ITS-90 coefficients included. Optional accredited calibration available from Hart. 

Immersion 

At least 100 mm (4 in) recommended 

Accuracy (includes calibration uncertainty and short-term stability) 

±0.050 °C at –196 °C
±0.050 °C at 0 °C  
±0.051 °C at 200 °C  
±0.055 °C at 420 °C  

Size 

5627A-12:12 in L x 1/4 in Dia.
5627A-9: 9 in L x 3/16 in Dia.
5627A-6: 6 in L x 3/16 in Dia. 

When buying a PRT, performance isn’t the only criterion you need to look at. The real issues are price-to-accuracy and price-to-durability ratios. 

The 5627A probes have a temperature range up to 420 °C and an accuracy as good as ±0.05 °C. They come in three different lengths. (The six-inch and nine-inch model covers –200 °C to 300 °C.) Each instrument is shipped with its ITS-90 coefficients and a calibration table in 1 °C increments. 

One of the best features of this sensor is that it conforms to the standard 385 curve, letting you use your DIN/IEC RTD meters fully. Why use a probe that’s less accurate than your meter? 

The 5627A is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. (Bend, if any, should be specified at time of order.) 

Six-inch and nine-inch 5627s are calibrated at –196 °C, –38 °C, 0 °C, 200 °C, and 300 °C. For the 12-inch version, the point at 300°C is replaced with a point at 420 °C. 

Each probe is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer.

This probe is an excellent value. It has the price-to-accuracy and price-to-durability ratios you should demand in every  PRT you buy! 

Ordering Information 

5627A-6-X 

Secondary PRT, 152 mm x 4.7 mm (6 x 3/16 in), –200 °C to 300 °C 

5627A-9-X 

Secondary PRT, 229 mm x 4.7 mm (9 x 3/16 in), –200 °C to 300 °C 

5627A-12-X 

Secondary PRT, 305 mm x 6.35 mm (12 x 1/4 in), –200 °C to 420 °C 

2601 

Probe Carrying Case 

X = termination. Specify “B” (bare wire), “D” (5-pin DIN for Tweener Thermometers), “G” (gold pins), “I” (INFO-CON fo            r 1521 or 1522 Handheld Thermometers), “J” (banana plugs), “L” (mini spade lugs), “M” (mini banana plugs), or “S” (spade lugs). 

Downloads

Right click one of the following links and “Save Target As ...” to download the catalog pages/data sheet or a product User's Guide in Acrobat (.pdf)  format.

Catalog page(s)/data sheet
5627A PRT User's Guide

Use our feedback form for more information.

 

 

 

Send mail to webmaster@hartscientific.com with questions or comments about this web site.
Copyright © 1998-2007 Hart Scientific, Inc.
Last Modified: 02/07/08